| Design | DIN 41635 B
|
 |
 |
| Mechanical life endurance | 10E6
1E6
(versions with auxiliary actuator) |
 |
 |
| Contact resistance (new condition) | < 100 mOhm (1 A 12 V DC)
|
 |
 |
| Insulation resistance (new condition) | > 100 MOhm (500 V DC)
|
 |
 |
| Proof tracking | 175 PTI
|
 |
 |
| Protection type | IP 00
|
 |
 |
| Ambient temperature | -40 °C
... +100 °C
|
 |
 |
| Flammability | UL 94 V-2
|
 |
 |
| Glow wire test temperature | 850 °C
|
 |
 |
| Material additional actuator | PA glass fiber-reinforced (1) / stainless steel spring steel (6) |
| housing | PBTP
|
| connections | tinned
/ silver plated / blank (product-dependent) |
 |
 |
| Bounce time | < 5 ms
|
 |
 |
| Approval marks | CSA
/ UL
/ ENEC 10
/ ENEC 05
|
 |
 |
| Suitable for appliances of protection class | II
under compliance with the installation conditions required on the equipment side |